Profile II 滤芯

Standard Profile® II Filter Elements.

Available in RF Series, RMF Series and AB Series—Code 3 and Code 7.

描述

Profile® II filters are all polypropylene.The elements have an absolute-rated downstream section, and a continuously graded pore size upstream section, which increases service life many-fold.

The materials of construction - chemically resistant polypropylene – permit application in a very wide range of corrosive and non-corrosive fluids.The fibers in Profile II filters may be considered continuous.No binder resin is used – the fibers are “bonded” by intertwining during the manufacturing process.As a result, Profile II filters show no media migration.

The Profile II filter has numerous applications in a broad range of industries that include chemical, petrochemical, photochemical, pharmaceutical, biological, electronic, magnetic tape, electroplating, food and beverage, cosmetic, veterinary, medical and fermentation industries.即可作为预过滤器,也可用作最终过滤器。

返回顶部

Operating Characteristics

Recommended maximum pressure differential is 60 psi up to 30°C (86°F), 50 psi up to 50°C (122°F), 30 psi up to 70°C (158°F), and 15 psi up to 82°C (180°F).

For applications where the filters are heated for any reason above 122°F (50°C) and the temperature is then reduced by 36°F (20°C) or more, AB Series elements are recommended.See Bulletin PRO 400 and PRE-1 for more detailed information.

Table I. Profile II Cartridge Grades And Their Characteristics
Removal Ratings     Typical Clean Pressure Drop
液体供应 Gaseous Service 液体供应 Gaseous Service Typical Aqueous
Cartridge
Grade
Rating in µm At % Efficiency

99.9%



100%
DOP (0.3µm)(1)
Efficiency %
Aqueous Pressure
drop(2)
CFM of air per
PSIper 10" cartridge(3)
Flow
(GPM/10" Cartridge)
003* <0.5(4) <0.5(4) 大于10000 3.5 2.3 1 - 2.5
005 <0.5(4) <0.5(4) 大于10000 2.8 2.7 1 - 2.5
010 <0.5(4) 1 大于10000 2.6 3.6 1 - 3
030 2.5 3 大于10000 1.5 6.4 2 - 5
050 4 5 大于10000 0.8 11.0 3 - 8
070 6 7 大于10000 0.5 17.0 5 - 12
100 9 10 99.2 0.3 29.0 6 - 15
120 11 12 96.5 0.2 36.0 6 - 15
150 13 15 88 0.15 44.0 8 - 15
200 18 20 84.8 0.10 75.0 10 - 15
300 26 30 67 0.08 119.0 10 - 15
400 35 40 48.3 0.05 207.0 10 - 15
700 70 (5) 34 <0.05 415.0 10 - 15
900 90(4) (5) 25 <0.05 640.0 10 - 15
1200 120(4) (5) 10 <0.05 1000.0 10 - 15

(1) Air flow used for these data was 20 cfm/10" module, except grade 700, which was run at 4 cfm.
(2) Pressure drop is PSI per GPM for a single 10" module.For multiple elements, divide by number of modules.For fluids other than water, multiply by viscosity in centipoise.
(3) For longer modules, increase the flow rates listed in proportion.The flow rates listed do not take into account pressure losses due to flow in the internal diameter of the element, which becomes significant above about 40 to 60 cfm.
(4) Extrapolated values.
(5) Precise evaluation of the 100% removal efficiency for these coarse grades is not possible with test procedure utilized.
* AB style only.


返回顶部

Sizes

The Profile II RF, and RMF Series filter elements are 21/2" O.D. and are available in one piece 10", 20", 30", and 40" length modules.Profile II elements are also available in 23/4" diameter

AB Code 3, 7 and 8 Series configurations.See Bulletin PRO 400 for further details.

返回顶部

Part Numbers / Ordering Information

Table II. Standard Configurations of Profile II Cartridges

  Profile II Element Part Numbers  
100% Removal Rating, µm For General Application For General Application Including In-Situ Steam Sterilization,and In-Situ Hot Water Sanitizing(1)
  RF Series AB Series
0.3* (2) AB Y003
0.5 (2) R F005 AB Y005
1 R F010 AB Y010
3 R F030 AB Y030
5 R F050 AB Y050
7 R F070 AB Y070
10 R F100  
12 R F120  
15 R F150  
20 R F200  
30 R F300  
40 R F400  
70 R F700  
90 R F900  
120 R F1200  

 
Gasket Code
No Symbol
Elastomeric Material** M***



   
Nominal Length, In. Code
10 1
20 2
30 3
40 4



 
Gasket Material Code
Alloy of Polypropylene and Ethylene Propylene Diene Monomer (EPDM) H21



 
应用 Code
制药 P
其它 Omit



 
O-Ring Option Code
Silicone H4
Viton A H
Ethylene-Propylene J



         
Cartridge Diameter O.D., In. Adapter Configuration Number of O-Rings O-Ring Size FDA Listed Materials of Construction Code
2 3/4 Flat Top 2 222 3
2 3/4 Finned Top, Locking Tabs 2 226 7
2 3/4 Finned Top 2 222 8

(1) Only P grade AB Series elements may be in-situ steam sterilized.
(2) Extrapolated valves.
* AB style only.
** Provides a positive sealing surface to eliminate potential fluid bypass in competitive housings with blunt knife edges.
*** When the M symbol is selected the part number must end in H21 code.





Table III.Housings For Profile II Elements

Type Of Element Housing Available
R  F Series and RM F Series See Housing Data Sheets H2, H13, H14, H15, H16, H17, H18, H19, H36, H37, H38 and H39 for 颇尔 housings specifically designed toaccommodate these elements.
R  F Series elements may also be used with competitor built housings which accommodate 21/2" O.D. x 10", 20", 30", and 40" nominal length elements; however,sealing may be marginal for grades 030 (3µm absolute) and finer.
AB  Y Series, Code 3, 7 and 8 See Housing Data Sheets H22, H26, H28, H29, H30, H31, H32, and H35.


返回顶部